Home › Products Featured Products Electrophoresis
SERVALight PreMix Chemiluminescence HRP Substrates - Save Time, Increase Consistency in Results
- Ready-to-use solution, no mixing of two components necessary
- Three detection ranges: mid pico-, mid femto- and low femtogram range
- Optimized signal/noise ratio
- Extended signal duration of 2 to 4 hours
- Excellent stability - >1 year stable at room temperature
42655 SERVALight PreMix Vega42656 SERVALight PreMix Eos
42657 SERVALight PreMix Helios
SERVA PRiME Lightning Red - Easy Labelling of Proteins prior to SDS PAGE and Western Blotting
- Simple and fast fluorescent pre-labelling of proteins for SDS PAGE and Western Blotting
- No need for protein concentration measurement, purification or concentration steps before or after labelling
- No staining and washing steps after the run
- Broad protein concentration range
- Very high sensitivity, very low background
- Wide dynamic and linear range
- Compatible with all common gel electrophoresis buffer systems and mass spectrometry
43402 SERVA PRiME Lightning Red
SERVA HPE Lightning Red - Fluorescent Pre-labelling of Proteins in 2D PAGE
Fluorescent dye for rapid and easy labelling of proteins prior to 2D PAGE - get better results with reduced costs and labor
- No clean-up or centrifugation steps after labelling necessary
- Compatible with all additives inclusive carrier ampholytes and denaturing agents
- No need for pH adjustment
- No staining and washing steps after the run
- Very high sensitivity, < 100 pg protein / spot
- Wide dynamic and linear range of > 104
- No over-staining effects as with silver staining
- Compatible with mass spectrometry and western blotting
BlueBlock PF (10x) for Blotting and ELISA - Save Time without Loss in Sensitivity
- Short incubation time and increased signal intensity
- Complete procedure in only 1 - 2 h with All-in-One protocol
- Suitable for colorimetric, chemiluminescence and fluorescence detection systems
42591 BlueBlock PF (10x)BlueClear SB for Fast and Efficient Antibody Stripping
- Fast, simple and highly effcient
- Gentle
- Without β-mercaptoethanol or DTT
- Suitable for nitrocellulose and PVDF membranes
42599 BlueClear SB for antibody strippingXpress Blotting Kit - Fast and Efficient Protein Transfer in Only 15 min
- Blotting Fleece instead of several layers of blotting paper for undisturbed transfer
- Ready-to-use – no preparing of buffer or cutting
of blotting papers or membranes
- Compatible with nitrocellulose and PVDF membranes
42662 Xpress Blotting Kitof blotting papers or membranes
42663 Xpress NC Blotting Kit
42664 Xpress PVDF Blotting Kit
SERVALight Vega HRP WB Substrate - Superior Performance and Less Costs
- No need to change protocol when switching from other standard ECL substrates to SERVALight Vega
- High signal intensity, mid-picogram limit of detection
- Low background even after long exposures
- High signal/noise ratio
- Working solution is stable for minimum 5 days – reproducible results, less waste
- Primary antibody dilution 1:100 -1:5000
- Secondary antibody dilution 1:1000 – 1:15.000
42588 SERVALight VegaSERVAColor BCIP/NBT Blot Solution - Highly Sensitive Single Component AP-Substrate Solution
- Rapid precipitate formation due to high activity
- High contrast due to very low background
- Long term stability at room temperature
- No significant fading after reaction stop
15245 SERVAColor BCIP/NBT Blot SolutionSERVAColor TMB Blot Solution - Highly Sensitive Single Component HRP-Substrate Solution
- Rapid precipitate formation due to high activity
- High contrast due to very low background
- Long term stability at room temperature
- No significant fading after reaction stop
37071 SERVAColor TMB Blot SolutionSERVA HiSens Stain G - Highly Sensitive, Non-Carcinogenic, Non-Toxic Fluorescent Nucleic Acid Stain
- Ready-to-use 10 000x stock solution
- Optimized for in-gel staining of agarose gels
- Sensitivity in in-gel staining is around 0.1 ng of DNA and 1 ng of RNA
- Can be detected with standard UV as well as with blue light tables
39805 SERVA HiSens Stain GSERVA Unstained Protein Standard IV
- For precise molecular weight determination in SDS PAGE
- Ready-to-use, no reconstitution, further dilution or heating required
- 12 recombinant proteins (10 kDa to 200 kDa)
- 25 kDa and 85 kDa bands with double intensity for easy allocation of molecular weights
- No refrigerated transport because stable for two weeks at 25 °C and up to 3 months at 4 °C
39250 SERVA Unstained Protein Standard IVSERVA VisiBlot Standard I
- 10 recombinant proteins (25 kDa to 150 kDa)
- Prestained bands (25 kDa, 45 kDa, 85 kDa) for monitoring electrophoresis and membrane transfer
- Accurate molecular weight determination of proteins detected on transfer membrane
- Ready-to-use, no reconstitution, further dilution or heating required
- Visualization of marker proteins on Western Blots by peroxidase or alkaline phosphatase-based immune-detection methods
39260 SERVA VisiBlot Standard ISERVA BlueBlot Semi-Dry Blotter
The BlueBlot semi-dry blotter forms a homogeneous electrical field that guarantees fast and efficient transfer of proteins from gel to membrane.
It is available with blotting areas of 11 cm x 11 cm, 17 cm x 17 cm and 24 cm x 26 cm. For the two smaller units, both electrode pairs (11 cm and 17 cm) will fit into the same base housing, what makes the blotter very flexible for small and larger gels.
With the 24 cm x 26 cm unit large gels like the horizontal HPE™ 2D gels can be blotted.
The key features:
- Platinum-covered steel net as anode
- Stainles steel plate as cathode
- Deployable for thicker gels and blotting stacks
- Blotting area from 11 cm x 11 cm up to 24 cm x 26 cm
SERVA BlueBlot (#BB-SD17
SERVA BlueBlot (#BB-SD26)
SERVAGel TG PRiME
- Precast Tris-Glycine mini vertical gels with long shelf life (12 months from production)
- Now available with 15 wells (8 %, 10 %, 12 %, 14 %, Gradient 4-12 %, 4-20 % und 8 - 16 %)
- Sample volume: 20 µl (50 µl with 10 well - and 35 µl with 12 well comb)
- High resolution with excellent band sharpness in only approx. 35 min
SERVAGel Precast gels - OverviewGeneGnome XRQ
The GeneGnome XRQ is dedicated to chemiluminescence imaging. The system is built for high performance and automation and features a next generation high quantum efficiency CCD camera for even greater sensitivity. A very simple set-up process means a single click will automatically capture a quality image of any Western blot.
- Optimized for imaging chemiluminesence Western blots
- Sensitive, high quantum efficiency cooled CCD camera (73 % @ 425 nm)
- Blot size 11 cm x 8 cm
- Small footprint (w 38 cm, d 39 cm, h 46 cm, 11.15 kg)
- Available in three variants:
o GeneGnome XRQ complete with monitor and built-in processor
o GeneGnome XRQ-NM complete with built-in processor but no monitor
o GeneGnome XRQ-NPC with no monitor or built-in processor
GeneGnome XRQ-NM
GeneGnome XRC-NPC
SERVA BlueCube 300
The SERVA BlueCube 300 is equipped with a CMOS camera, a built-in UV transilluminator, a filter changer including an UV filter, as well as a gel capturing and analysis software (GelView 1D).
It is suitable for documentation of DNA gels stained with ethidium bromide, but also for gels stained with DNA Stain Clear G or similar.
A magnetic shield protects the user when cutting out DNA bands from the gel. With dimensions of 30 x 26 x 24 cm and a weight of 10.4 kg only, it is a very compact and bench place saving system.
- Integrated UV transilluminator
- Gel area is 18 x 14 cm
- Automatic UV light shut-off
- High performance and easy handling system at a low price
- With the SERVA BlueCube 300L version, an external computer is included
SERVA BlueCube 300L